1 - NEW IMPERIAL SYSTEMS CMAXX DUST COLLECTOR, MODEL #: CM002

Brand
Not Specified

Model
CM002

Stock #
85079

Condition
New

Year
N/A

Equipped With

SPECIFICATIONS:
Make: Imperial Systems
Equipment Type: CMAXX
Model: CM002
Application: dry dust
Total CFM: 1,800
Total Filtration Media Area: 800 ft²
Air to Media Ratio: 2.25:1
Imperial Systems CMAXX:
The CMAXX™ was designed to be the strongest, safest, and most efficient dust and fume collector in the industry. it offers unique features found in no other dust collector. With powerful DeltaMAXX™ PRIME filters, the CMAXX™ features improved filter life, better pulse cleaning, and higher efficiency.
Filter Pulse Cleaning System:
·         High-efficiency manifold-mounted pulse valves
·        Factory assembled and tested
·         NEMA 4 solenoid enclosure
·         Factory-mounted pressure gauge on compressed air manifold
Housing:
·         The only modular dust collector with no external bolt holes
·         No leaks, backed up by our Lifetime Warranty
·         CrownTech domed roof improves weather resistance and prevents rusting
·         Stainless steel external hardware
·         7ga. and 10ga. construction
·         Industrial-grade textured powder coat
·         Meets 3,000-hour salt spray test based on ASTM B117-97 on standardized test panels
·         60° sloping hopper with standard 10" square flange discharge (Other sizes available)
Filter Access:
·         Military grade door latches for durability
·         Tool-free single-handed operation
·         Lockable door handle
·        Tool-free filter change out with Even Lock™ technology
CMAXX Safety Pentagon:
The CMAXX is outfitted with the most innovative features including a redundant safety design.
The features include:
·         Anti-Ramp Lift Rails - Stops filters from overlapping each other
·         Double Gasketed Filters - Double layer of protection to ensure a good seal
·         Completely Grounded - Filters are grounded to the dust collector
·         Lift Rail Door Stop - Stops the door from closing if the lift rails are not in the proper upright position
·         Sure-Stop System - Ensures filters are installed properly or the door will not close, using pan indexing channel and door indexing bar
Structure:
·         Powder coated to match filter housing
·         Seismic zone 3 construction based on 100 MPH wind load
·         Bolted construction
·         54" Clearance for 55ga. drum and drum cover kit (Additional height optional)
DeltaMAXX PRIME 400 sq. ft Nanofiber Fire Retardant (Quantity 2):
·         Nanofiber technology with a MERV 15 rating based on ASHRAE 52.2 testing, efficient down to 0.3 microns particle size
·         Double gaskets to prevent any leaks
·         SURE-STOP system interlocks with filter pan, preventing door from closing unless filters are correctly installed
·         Unique grounding tab to prevent static buildup
·         Oval shape to maximize rectangular pan space
·         Fire retardant coating for spark and flame resistance
·         Rated to 180 degrees F.
High Entry Inlet Staggered Angle Inlet Baffle:
·         High Entry Inlet allows the material to come in at filter level causing a natural downflow cleaning effect
·         The inlet section is protected by our unique streamline Staggered Angle Baffles. These Baffles provide protection to the filters from abrasive material with minimum pressure loss
·         Baffles bolt in and can easily be replaced
·         Standard bolt on inspection door on inlet chamber
Drum Cover Kit(s) - 10" (254 mm) Dia with Manual Slide Gate:
·         Kit includes manually operated slide gate(s) with a 55ga. clamping drum lid and a flexible hose connector
Dwyer DCT1000 Control:
·         This control manages the Pulse Filter Cleaning System
·         Software menu that is easily accessible and is designed so that you do not need an instruction manual
·         There are no cumbersome menu keystrokes or passwords required to access the DCT1000
·         High/low limit control capability from an external source such as the Dwyer Photohelic® Switch/Gage
·         Solenoid time/on-time/off settings
·         A universal power supply to meet domestic and overseas requirements
·         Auto/manual control capability so you always have control over the system
·         Downtime cleaning feature that allows for time based pulsing at the end of a plant shift or for completing a batch process
·         Easily select the number of output channels
Equipment Type: CMAXX Fan
Model: MS-9-RB-75-10 Fan
Application: dry dust
Total CFM: 1,800
Total Static Pressure: 12.0 inches W.G.
MS-9-RB-75-10 Fan:
·         10 HP 230/460/3/60 Premium E motor
·         Top-mounted heavy-duty construction
·         Backward-inclined fan wheel
·         Optional side mounted fan to reduce overall height available with additional cost by request
Slide Gate Damper
·         Manual air damper on the fan outlet
Equipment Type: CMAXX Control Panel
Model: 10 HP Control Panel
Application: dry dust
Horsepower: 10
10 HP Control Panel
·         NEMA 4 enclosure
·         Main breaker with handle
·         IEC fan starter
·         Maintained E-stop switch
·         110V Control transformer
·         Illuminated push/pull operator
·         Continuous/on-demand selector switch
·         Local remote selector switch
·         Imperial-supplied DCT timer board
·         Window kit
·         High and low differential pressure connection ports in bottom of panel
·         Wired with UL listing
·         Wiring for optional solenoid heater
OPTIONAL FEATURES:
Optional CM002 (CMAXX) Items:
Sprinkler System:
·         Glass Bulb style sprinkler head(s)
·         Collector is plumbed at factory and shipped with sprinkler heads
Price  .  .  .  .  .  .  .  .  .  .  .  .  $712.00
Compressed Air Regulator:
·         The CMAXX comes standard with a pressure gauge
·         This is a recommended option for regulating the recommended 80 to 90 PSI of compressed air pressure
·         Includes air filter
Price  .  .  .  .  .  .  .  .  .  .  .  .  $445.00
Solenoid Heaters:
·         120V heaters internally mounted. This heater prevents solenoids from failure during freezing conditions. Remote thermostat included
Price  .  .  .  .  .  .  .  .  .  .  .  .  $712.00
Optional MS-9-RB-75-10 Fan (CMAXX Fan) Items:
Fan Silencer:
·         Fan Silencer bolts directly to fan outlet
·         Requires supports from ceiling or ground (Not included)
·         Reduces noise to below 85DB or lower at 5’
Price  .  .  .  .  .  .  .  .  .  .  .  .  $3,629.00
Imperial Systems Equipment Onsite Start-Up Service Commissioning and Customer Training:
An Imperial Systems Service Technician will carry out equipment start-up, system inspection, and training of key personnel. This service may include:
Visual Inspection:
·         Ensuring the machine is properly sealed and installed per assembly instructions
·         Checking for all proper electrical connections and functions
·         Ensuring installation matches approval drawings regarding orientations
·         If applicable, verifying that all deflagration and fire protection components are installed properly with proper orientations
Operating Parameters Inspection:
·         Measuring the inlet airflow and ensuring it matches designed flow
·         Checking static pressure to ensure that it matches designed start-up range
·         Checking controls, if supplied by IS, for proper connections and operation per specification
Machine, controls, and maintenance training:
·         Control panel programming and adjustments
            The anticipated time required is one (1) standard business day on straight time. This cost includes technical labor, expenses, lodging, per diem and travel. Additional subsequent days will be at a cost of $1,850 per man at straight time and includes listed expenses. Overtime that exceeds 10 hours, weekend labor (Saturday and Sunday), or holiday labor will be charged at a current price schedule which is available upon request. All equipment needed to do the start-up such as man lifts, cranes, forklifts, etc. will be at the cost and the responsibility of the customer unless otherwise agreed upon by both parties.
           Please note that price listed is good only if start-up is scheduled 18 full business days in advance of the requested date given to Imperial Systems or additional expedite charges may apply. If the work is canceled, rescheduled, or delayed by the customer at any time prior to the given / scheduled date, the customer will be responsible for travel changes, penalty costs, and additional cost per hour at the rate listed above.
This start-up is not an installation service. All equipment must be fully installed, wired, bump tested, and ready to run prior to a technician visit. Items that need completed prior to on-site start-up, commissioning, and training:
·         Main power run to control panel and checked for proper connections
·         Power run from control panel to blower, pulse cleaning solenoids, any other ancillary equipment
·         Compressed air piping connected to collector
·         Ducting fully installed
·         Differential pressure tubing ran between dust collector and control panel
          Some specialized equipment including, but not limited to, chemical explosion/fire suppression and spark detection equipment may need a commissioning or startup by a third-party certified technician. Pricing for that equipment is available by request and is not included in the below price.
Total Cost for Service  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  $4,894.00
6 Month Inspection and Follow Up Training .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .   $4,894.00
Add **$1,150 to each service for Mountain and Pacific Time Zones. Out of the United States to be quoted independently.
DELIEVERY:
5-7 WEEKS FOR SHIPMENT

 

 

 

Not Quite What You're Looking For?

Our knowledgeable staff will assist you with all of you questions.

Contact Us